For sales and support visit:
hubbellpowersystems.com/contact/

Super Top-Tie® Line Ties

For Pin, Post and Spool Insulators

ALUMINUM COATED STEEL
STT

Made of aluminum-clad steel compatible with aluminum, aluminum-alloy and ACSR conductors in the top grooves of vertical-mounted *ANSI Class C, F, J and many non-standard pin and post insulators (single- or double-support) or on *ANSI 53-2 spool insulators (horizontal or vertical).

High-density polyethylene hooks provide the wide application range and ensure proper installation. If used over armor rods (not required), select tie size based on total conductor/armor diameter. Semiconductive-rubber pad and high-densitypolyethylene on loops protect against abrasion of insulator, conductor and tie. Fit is resilient and provides superior performance under galloping and aeolian vibration. Install by hand or with hot-line tools.

*Super Top-Tie STT10 - STT130 also fit many foreign or reclaimed pin and post insulators with neck sizes 2-1/4" - 3-1/2".
Consult Hubbell Power Systems, Inc. for use on pins and posts outside these dimensions.

Catalog Number Aluminum-Type Conductors, Typical Sizes Diameter Range in. (cm) Conduct. Color Code STD. PKG. Wt. Per 100, LB. (KG)
ACSR AAC AAAC MIN. MAX.
STT10 #6 (6/1) #6 (7W) #6 (7W) 0.184 (4.67) 0.220 (5.59) NONE 50 28 (12.7)
STT20 #4 (6/1) #4 (7W) #4 (7W) 0.221 (5.61) 0.257 (6.53) ORANGE 50 28 (12.7)
STT40 #2 (6/1) #2 (7W) #2 (7W) 0.290 (7.37) 0.325 (8.26) RED 50 28 (12.7)
STT50 #1 (6/1) #1 (7W) #1 (7W) 0.326 (8.28) 0.360 (9.14) GRAY 50 28 (12.7)
STT60 1/0 (6/1) 1/0 (7W) 1/0 (7W) 0.361 (9.17) 0.409 (10.39) YELLOW 50 32 (14.5)
STT70 2/0 (6/1) 2/0 (7W) 2/0 (7W) 0.410 (10.41) 0.460 (11.68) BLUE 50 32 (14.5)
STT80 3/0 (6/1) 3/0 (7/W) 3/0 (7/W) 0.461 (11.71) 0.516 (13.11) BLACK 50 32 (14.5)
STT90 4/0 (6/1) 4/0 (7W) 4/0 (7W) 0.517 (13.13) 0.584 (14.83) PINK 50 32 (14.5)
STT100 266.8 (18/1) 266.8 (19W) 266.8 (19W) 0.585 (14.86) 0.664 (16.87) GREEN 50 32 (14.5)
STT110 336.4 (18/1) 336.4 (19W) 336.4 (19W) 0.665 (16.89) 0.755 (19.18) BROWN 50 40 (18.1)
STT120 477 (18/1) 477 (19W) 477 (19W) 0.756 (19.20) 0.859 (21.82) VIOLET 50 40 (18.1)
STT130 556.5 (18/1) 636 (37W) 556.5 (19W) 0.860 (21.84) 0.977 (24.82) GOLD 50 40 (18.1)

Left-Hand Lay Standard

  • Applied Length: 29" - 48" (Depends on insulator make and conductor size).
  • Strength: Exceeds Rule 261E.2(A) of National Electrical Safety Code.
  • RUS accepted.